The XG2038 is a world-class portable overall measuring instrument with many testing functions for PCM channel characteristics (both full-channel and half-channel), and error testing for E1 as well, based on multi-task OS of Win CE.
It can be used to measure PCM device, digital switch, carrier wave communication device, client's dispatching equipment, digital broadcasting station with voice channel interface and VoIP device, especially applicable to science research, manufacturing, engineering installation, check and acceptance as well as maintenance.
1. Basic Functions
- Voice channel Characteristics testing
√ A-A: Level, Variation of gain with frequency, Variation of gain with input level, Total distortion including quantizing distortion, Idle channel noise, Crosstalk, Return loss, Longitudinal conversion loss, Longitudinal conversion transfer loss.
√ A-D, D-A, D-D: Level, Variation of gain with frequency, Variation of gain with input level, Total distortion including quantizing distortion, Idle channel noise, Crosstalk
- 2M (E1) frame and unframed BER testing, alarm detection and error analysis
- Call set-up: support on-hook, off-hook, dialing, ringing, and ringing supervise
- Auto and manual mode available, on the auto mode, all or one or several of the above performance characteristics can be selected to measure
- Support test of frequency spots sequence of equal step and customized frequency spots, and the number of spots is optional
- Support selective frequency measuring on all frequency spot
- Results are shown graphically, and can be compared with the built-in reference module to evaluate whether it passes or fails
- Perfect indication of working state and alarm
- Large storage capacity of results and measuring configurations, up to 100 groups
- Available in remote control via USB and Ethernet interface, to meet the need of different control modes
- Results can be uploaded to PC, so as to be analyzed, assembled, filed and printed via TestManager Pro software
2. Main Features
- Overall functions, satisfy users’ measuring requirements
- Integrated with tone oscillator, Selective Frequency Meter, BER tester and Call Generation, more PCM channel characteristics can be measured one time
- 5.7 inches 640X480 high-resolution colorful LCD display
- Flexible control modes, supporting touch operation, key-stroke operation and expanded mouse operation
- Convenient Windows style, easy to operate
- Built-in call set-up circuit, can set up testing channel directly by dialing on the tester without the help of other telephone
- Built-in generator and receiver, analog input and output interfaces are separately with ICT and OGT. Interfaces can be directly tested, including 2/4W E&M, MDR, LGE, FXO, LGS and FXS
- Built-in balanced bridge and reflecting bridge, Return loss, Longitudinal conversion loss and Longitudinal conversion transfer loss can be measured by one tester
- Built-in test mode can be defined by clients, efficiently satisfying testing standard definition of different products
- Remote control signaling group is available, so as to secondarily develop under different conditions by clients
- Embedded software can be upgraded online and protect the client’s investment
3. Configurations
|
Item |
QTY |
Item |
QTY |
|
PCM Channel Analyzer |
1 |
Stylus |
1 |
|
AC Power Adapter |
1 |
Portable bag |
1 |
|
Special Testing Cable |
1 |
Quality Certificate |
1 |
|
USB communication Cable |
1 |
User’s Manual |
1 |
|
TestManager Pro (CD) |
1 |
Maintenance Card |
1 |
|
Packing List |
1 |
4. Specifications
|
|
Item |
Description |
|
|
Analog
Loop
|
Generator |
Sine wave signal output |
Frequency Range |
200Hz~3600Hz,Step:1Hz |
|
|
Level |
+5dBm0~-60dBm0,Step: 0.1dB |
|
|
Distortion Rate |
1020Hz,0dBm0,<-55dB |
|
|
Variation of Frequency Response |
±0.1dB |
|
|
Receiver |
Level |
Range |
200Hz~3600Hz |
|
|
Level Range |
+5dBm0~-60dBm0 |
|
|
Error Range |
±0.1dB |
|
|
Variation of Gain with Frequency |
Reference Frequency |
1020Hz,-10dBm0 |
|
|
Measuring Range |
+200Hz~3600Hz |
|
|
Error Range |
±0.1dB |
|
|
Variation of Gain with input Level |
Reference Frequency |
1020Hz,+5dBm0~-56dBm0 |
|
|
Measuring Range |
+20dB~-20dB |
|
|
Error Range |
±0.1dB |
|
|
Total
Distortion |
Reference Frequency |
1020Hz,-56 dBm0~+5 dBm0 |
|
|
Measuring Range |
0~-40dB,ITU-T Weighted |
|
|
Error Range |
±0.8dB |
|
|
Idle Channel Noise |
Secondary Signal |
420Hz,-45dBm0 |
|
|
Measuring Range |
+5~-110 dBm0,ITU-T Weighted |
|
|
Error Range |
±0.5dB |
|
|
Crosstalk |
Main-crosstalk Signal |
1020dB,0 dBm0 |
|
|
Measuring Range |
+5~-75 dBm0 |
|
|
Error Range |
±1 dBm0 |
|
|
Return Loss |
Range |
200Hz~3600Hz |
|
|
Level Range |
+5dBm0~-60dBm0 |
|
|
Error Range |
±0.2dB |
|
|
Longitudinal Conversion Loss |
Range |
200Hz~3600Hz |
|
|
Level Range |
+5dBm0~-60dBm0 |
|
|
Error Range |
±0.2dB |
|
|
Longitudinal Conversion Transfer Loss |
Range |
200Hz~3600Hz |
|
|
Level Range |
+5dBm0~-60dBm0 |
|
|
Error Range |
±0.2dB |
|
|
Interface Type |
FXO(LGE),FXS(LGS),2/4W E&M
(Balanced, unbalanced), MDR |
|
|
Interface Impedance |
600W,200W+560W//0.1uF,200W+680W//0.1uF
Output 0Ω and Hi-Z input |
|
|
Relative Level |
Transmitted end:+1dBr~-16dBr,Step:0.1dBm
Received end:+7dBr~-10dBr,Step:0.1dBm |
|
|
DC Loop |
ICT: Dynamic impedance>100KΩ
Loop Current: max. 60mA
Loop Voltage :approx. 18V;
OGT:Dynamic impedance >100KΩ,
DCHC :25mA |
|
|
Digital
Loop |
|
Sine wave signal output |
Frequency Range |
200Hz~3600Hz,Step:1Hz |
|
Level Range |
+3dBm0~-56dBm0,Step:0.1dB |
|
Distortion Range |
1020Hz,0dBm0,<-46dB |
|
Noise signal output |
Transmitted Frequency |
350Hz~550Hz |
|
Transmitted Level |
0dBm0 |
|
Error Range |
±0.5dB |
|
Receiver |
Level |
Frequency Range |
200Hz~3600Hz |
|
Level Range |
+3dBm0~-60dBm0 |
|
Frequency
Response |
Reference Frequency |
1020Hz,-10dBm0 |
|
Measurement Range |
+200Hz~3600Hz |
|
Error Range |
+3 dBm0 ~ -40 dBm0 |
±0.3dB |
|
-40 dBm0 ~ -50 dBm0 |
±0.6dB |
|
-50 dBm0 ~ -55 dBm0 |
±1.6dB |
|
Variation of Gain with input Level |
Reference Frequency |
1020Hz,0dBm0 |
|
Measurement Range |
+3dBm0~-56dBm0 |
|
Error Range |
+3 dBm0 ~ -40 dBm0 |
±0.3dB |
|
-40 dBm0 ~ -50 dBm0 |
±0.6dB |
|
-50 dBm0 ~ -55 dBm0 |
±1.6dB |
|
Total
Distortion |
Noise |
Frequency Range |
350Hz~550Hz |
|
Level Range |
+3dBm0~-60dBm0 |
|
Tone |
Frequency Range |
200Hz~3600Hz |
|
Level Range |
+3dBm0~-60dBm0 ITU-T Weighted |
|
Error Range |
+3 dBm0 ~ -40 dBm0 |
±0.3dB |
|
-40 dBm0 ~ -50 dBm0 |
±0.6dB |
|
-50 dBm0 ~ -55 dBm0 |
±1.6dB |
|
Idle Channel Noise |
Measuring Range |
+0~-110 dBm0,ITU-T Weighted |
|
Error Range |
±1dB |
|
Crosstalk |
Main-crosstalk Signal |
1020dB,0 dBm0 |
|
Measuring Range |
+3~-80 dBm0 |
|
Error Range |
±1 dBm0 |
|
Other |
Interface Impedance |
75Ω、120Ω |
|
Frame Type |
PCM30/30CRC、PCM31/31CRC |
|
Coding Method |
A -rule, μ-rule |
|
Output Code |
HDB3、AMI |
|
E1
Error
Testing |
Basic
Settings
|
Interface Impedance |
75Ω、120Ω |
|
Frame Type |
PCM30/30CRC、PCM31/31CRC、Non-frame |
|
Coding Method |
A -rule, μ-rule |
|
Output Code |
HDB3、AMI |
|
Testing Pattern |
220-1、215-1、211-1、29-1、27-1、1111、0000、1010、32bit programmable |
|
Transmitted Clock |
Internal, interface |
|
Result
Analysis |
Alarm Second |
Signal loss, frame alignment, AIS, Multiframe alarm |
|
Signal Analysis |
Line rate, Frequency Offset |
|
Basic Analysis(BIT、CODE、FAS) |
Error, CER, EFS, AER |
|
G.821Analysis |
ES, DM, SES, Unavailability |
|
TestManager Pro |
Support WIN98/NT/ME/2000/XP |
|
|
Power Supply |
AC220V±10%,50Hz |
|
|
Dimension |
293mm×195mm×56mm(L×W×H) |
|
|
Working Temperature |
0℃~50℃ |
|
|
Storage Temperature |
-20℃~70℃ |
|
|
Humidity |
5%~95% non-condensing |
|
|
Weight |
Approx. 1.8kg |
|
|